SINAMICS G180 2T3F-87401-400 230-415V TN/TT, 50/60 Hz Motor output (typ.) 400kW (400V) HWD without opt. on request IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, Second environment C3
SINAMICS G180 2T3F-87401-500 230-415V TN/TT, 50/60 Hz Motor output (typ.) 500kW (400V) HWD without opt. on request IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, Second environment C3
SINAMICS G180 2T3F-87401-560 230-415V TN/TT, 50/60 Hz Motor output (typ.) 560kW (400V) HWD without opt. on request IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, Second environment C3
SINAMICS G180 2T3F-87401-630 230-415V TN/TT, 50/60 Hz Motor output (typ.) 630kW (400V) HWD without opt. on request IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, Second environment C3
SINAMICS G180 2T3F-87501-250 230-500 V IT, 50/60 Hz Motor output (typ.) 250kW (500V) HWD without opt. on request IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T3F-87501-315 230-500 V IT, 50/60 Hz Motor output (typ.) 315kW (500V) HWD without opt. on request IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T3F-87501-630 230-500 V IT, 50/60 Hz Motor output (typ.) 630kW (500V) HWD without opt. on request IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T3F-87501-710 230-500 V IT, 50/60 Hz Motor output (typ.) 710kW (500V) HWD without opt. on request IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T3F-87501-800 230-500 V IT, 50/60 Hz Motor output (typ.) 800kW (500V) HWD without opt. on request IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T3F-87601-315 400-690V IT, 50/60 Hz Motor output (typ.) 315kW (690V) HWD without opt. on request IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T3F-87601-400 400-690V IT, 50/60 Hz Motor output (typ.) 400kW (690V) HWD without opt. on request IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T3F-87601-500 400-690V IT, 50/60 Hz Motor output (typ.) 500kW (690V) HWD without opt. 2002*1406*605 mm IP21 air-cooled, 12-pulse line reactor, DV/DT Output filter EMC EN61800-3